Three-phase: CIMR-LC2A_ | 0018 | 0025 | 0033 | 0047 | 0060 | 0075 | 0085 | 0115 | 0145 | 0180 | |
Motor kW | For HD setting | 4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 |
Output characteristics |
Inverter capacity kVA | 6.7 | 9.5 | 12.6 | 17.9 | 23 | 29 | 32 | 44 | 55 | 69 |
Rated output current (A) | 17.5 | 25 | 33 | 47 | 60 | 75 | 85 | 115 | 145 | 180 | |
Max. output voltage | Proportional to input voltage: 0..240 V | ||||||||||
Max. output frequency | 120 Hz | ||||||||||
Power supply | Rated input voltage and frequency | 3-phase 200..240 V 50/60 Hz | |||||||||
Allowable voltage fluctuation | -15%..+10% | ||||||||||
Allowable frequency fluctuation | +5% | ||||||||||
Input Current (A) | 18.9 | 28 | 37 | 52 | 68 | 80 | 82 | 111 | 136 | 164 |